VEGAPULS 61
Radar sensor for continuous level measurement of liquids
For simple process conditions
|
|
Application area
Your benefit
- Exact measuring results independent of process conditions
- High plant availability, because wear and maintenance-free
- Maintenance-free operation through non-contact measuring principle
Newer product available
There is a successor for this product. If you have any questions about the product, please contact your VEGA representative.
VEGAPULS 6XConfigure product
Product comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsContinuous level measurement of liquids – the reliable solution for simple applications
- 35 m [Meter - Foot]
- -40 ... 80 °C [°C - °F]
- -1 ... 3 bar [Bar - kPa - psi]
- ± 2 mm
- 26 GHz
- ≥ 10°
- with plastic horn antenna ø 80 mm
- Encapsulated horn antenna
- PVDF
- 316L
- PP
- G1½, 1½ NPT
- ≥ DN80, ≥ 3"
- Clamp ≥ 2", DN50 - DIN32676, ISO2852
- Slotted nut ≥ 2", DN50 - DIN 11851
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- Profibus PA
- Foundation Fieldbus
- Two-wire: 4 … 20 mA/HART
- Modbus
- Four-wire: 4 … 20 mA/HART
- -40 ... 80 °C
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- KOSHA / Korea
- NEPSI / China
- UKR Sepro / Ukraine
- IEC / Australia
- UKEX
- Intrinsic safety "i"
- Flameproof enclosure "d"
- ABS
- BV
- CCS
- DNV
- LR
- NK
- RINA
- RMROS
- WHG
- SIL2
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS™, PDM)
- Display/adjustment module PLICSCOM
- VEGADIS 81
- Pluggable display module PLICSLED
- VEGADIS 82
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowProduct information
VEGAPULS WL 61, 61, 62, 63, 64, 65, 66
Specification sheet
VEGAPULS 61
4 … 20 mA/HART - two-wire
Operating instructions
VEGAPULS 61
4 … 20 mA/HART - two-wire
Sensor
Drawing generator
Further downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsBluetooth USB adapter
Wireless adjustment of sensors and instruments via Bluetooth
Show ProductVEGADIS 81
Remote measurement value indication and adjustment of plics® sensors
SGD 540.00
VEGADIS 82
External measured value display and adjustment for 4 ... 20 mA/HART sensors
SGD 430.00
VEGADIS 176
Magnetic pen for display/adjustment module PLICSCOM
Magnetic pen for on-site adjustment
Show ProductVEGAMET 141
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
SGD 720.00
VEGAMET 142
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
SGD 940.00
VEGAMET 341
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
SGD 790.00
VEGAMET 342
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
SGD 1,000.00
VEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
SGD 850.00
VEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
SGD 1,070.00
VEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
SGD 1,190.00
VEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
SGD 1,430.00
VEGAMET 624
Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor
Show ProductVEGAMET 625
Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors
Show ProductVEGAMET 391
Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
VEGATOR 142
VEGASCAN 693
Measured value indication and remote enquiry of measured data for up to 15 HART sensors
Show ProductPLICSMOBILE T81
Measured data enquiry and remote parameter adjustment for a HART sensor
Show ProductVEGATRENN 141
VEGATRENN 142
VEGATRENN 151
Single channel separator in two-wire technology for 4 … 20 mA sensors
SGD 240.00
VEGATRENN 152
Double channel separator in two-wire technology for 4 … 20 mA sensors
SGD 350.00
Overvoltage protection B 81-35
Overvoltage protection B 63-32
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
SGD 300.00
Overvoltage protection B 63-48
Overvoltage protection B 62-30 W
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
SGD 210.00
Overvoltage protection B 62-36 G
VEGACONNECT
Interface adapter between PC and VEGA instruments
Show ProductVEGABOX 03
Breather housing with ventilation filter
Show ProductEthernet switch
up to 8 RS45 pluggable
Show ProductProfibus PA/DP segment coupler
Simple segment coupler for up to 93.75 kbit/s DP-side
Show ProductAdapter flanges VEGAPULS 6X / 61 / 67 / 69 / 64
The adapter flange is a retrofitting part for these radar sensors for connection to flanges on the plant side
Show ProductRinsing connection VEGAPULS 61, 64, 67, 69
The rinsing connection is an accessory part for VEGAPULS WL 61, 61, 67 and 69 radar sensors.
Show ProductMounting strap
For mounting of VEGA instruments.
Show ProductMounting bracket with 45° reflector
For mounting of radar sensors VEGAPULS 61 and VEGAPULS WL 61.
Show ProductProtective cover
The protective cover is an accessory or retrofit part for sensors from the VEGA plics® line of products.
Show ProductAntenna extension PLICSMOBILE
VEGADIS adapter
For connection of an external display and adjustment unit or a Secondary sensor.
Show ProductElectronics VEGAPULS series 60 plics®plus
Electronics VEGAPULS series 60 plics®
Process component VEGAPULS 61
Remote housing PLICS
Replacement housing for plics® instruments
Show ProductSingle chamber housing PLICS
The housing is a spare oart for sensors of the plics® family
Show ProductDouble chamber housing PLICS
The housing is a spare oart for sensors of the plics® family
Show ProductHousing cover PLICS
Plug connection PLICS
The plug connector is an accessory part for sensors with single or double chamber housing. It is used as separable connection to power supply or signal processing.
Show ProductPLICSMOBILE plug connector with SMA connection
Electronics PLICSMOBILE series 80
An error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGAPULS 61
myVEGA
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
Close