Pressure measurement in the water steam line
|
|
Process data
Measuring task:
Pressure measurement
Measuring point:
Steam line in the medium pressure range
Measuring range up to:
20 bar
Medium:
Steam
Process temperature:
+100 … +210 °C
Process pressure:
+6 … +20 bar
Special challenges:
High pressure and high temperatures
Application
The pressure in the steam loop has to be monitored at various points in the process. Reliable measurement is required especially at the inlets of the various pressure stages of the turbine. Pressure transmitters detect even the smallest changes in the steam loop in any state of operation.
Your benefit
Reliable
Reliable operation under all operating conditions
Cost effective
Optimal plant operation
User friendly
Simple installation and adjustment
Recommended products
VEGABAR 83
Pressure transmitter for pressure monitoring in the steam line
- Direct connection to process, even at high temperatures
- High accuracy, even in high-pressure applications
- Remote electronics ensures high operational reliability
Measuring range - Distance
-
Measuring range - Pressure
-1 ... 1000 bar
Process temperature
-40 ... 200 °C