Chlorine storage tank
Level measurement and point level detection in storage tanks for chlorine
|
|
Process data
Measuring task:
Level measurement and point level detection
Measuring point:
Tank
Measuring range up to:
10 m
Medium:
Chlorine
Process temperature:
-40 … +80 °C
Process pressure:
-1 … +16 bar
Special challenges:
Very aggressive medium with a strong tendency to diffuse
Application
Chlorine production and storage places high demands on the chemical and the diffusion resistance of the materials in the production equipment. Extensive process knowledge and experience is required when selecting the sealing materials. In fact it is decisive for the long-term, safe and profitable operation of the plant. Since the processes can only be interrupted at great expense and plant disruption, the reliability of the instrumentation is a top priority.
Your benefit
Reliable
All materials are fully chemically resistant
Cost effective
Universal application, independent of product characteristics and process conditions
User friendly
Maintenance-free operation
Recommended products
VEGAPULS 6X
Level measurement with non-contact radar sensor in the storage tank for chlorine
- Reliable level measurement under all process conditions
- Optimum chemical resistance is ensured by a diffusion-tight, 8 mm thick PTFE disc
- Maintenance-free operation with very long service life
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar
VEGASWING 63
Point level detection with vibrating level switch in the storage tank for chlorine
- Reliable level detection under all process conditions in wide temperature and pressure ranges
- Various highly resistant materials are available to meet widely different demands on chemical resistance
- Simple function check with test button on the sensor
Process temperature
-50 ... 250 °C
Process pressure
-1 ... 64 bar
Version
Standard
Hygienic applications
with gas-tight leadthrough
with tube extension
with temperature adapter